![]() |
Short Report
1 Product Specialist, Macopharma do Brasil, Brazil
2 Senior Medical Department, Macopharma, Tourcoing, France
3 Medical Department Director, Macopharma, Tourcoing, France
4 Head of Blood Bank, UMAE Hospital de Especialidades, Puebla, Mexico
5 Quality Control Coordinator Blood Bank, UMAE Hospital de Especialidades, Puebla, Mexico
6 Subdirector Technician, Centro de Sangre Valparaíso, Chile
7 Production Coordinator, Centro de Sangre Valparaíso, Chile
8 Blood Bank Director, Banco de Sangre de Córdoba, Montería, Colombia
9 Production Coordinator, Banco de Sangre de Córdoba, Montería, Colombia
10 Quality Control Coordinator, Banco de Sangre de Córdoba, Montería, Colombia
Address correspondence to:
Dalia María Moreno Cardona
Calle 45D No. 81-10 apto 1501, Medellín, Antioquia,
Pin- 50031, Colombia
Message to Corresponding Author
Article ID: 100055Z02DM2020
Aims: To explore the compliance with European standards for the quality control (QC) parameters of blood components production in Latin American blood banks, evaluating QC data results processed with red blood cell (RBC), and platelet concentrates (PL) produced.
Methods: An observational retrospective cross-sectional study was conducted with data from one year’s production QC data of platelet concentrate (PL) from the buffy-coat (BC) removal method. Red blood cell was collected in three blood banks from Mexico, Colombia, and Chile. Analysis of the quality limits established in each country was made using Pearson’s Chi-square test. Dunnett’s T3 test evaluated the comparative analysis of the mean. All the tests were performed with bilateral contrast, achieving statistical significance when p ≤ 0.05.
Results: The mean of the total results for the RBC evaluated was volume 277 mL ± 21; hematocrit (HCT) 58.7% ± 3.6; leukocytes (×109/mL) 0.47 ± 0.31. Results for PL were volume: 67 ± 10; platelet count (×109/mL): 76.8 ± 24; leukocytes (×109/mL) 0.02 ± 0.02. According to these total results, the compliance with respect to the control performed was for RBC: Volume 97.9%; hematocrit 98.8%; leukocytes 97%. For PL was 100% for volume; platelet count 82.3%; leukocytes 95.3%.
Conclusion: The QC results conclude that the RBC with the BC removal process produces high-quality components, with a reduced concentration of leukocytes, complying with European Union (EU) guidelines and allow to obtain single platelet from BC with high quality.
Keywords: Blood bank, Latin America, Platelets concentrate, Quality control, Red cell concentrates
Quality control (QC) in Latin American countries’ blood components has significantly impacted recent years. From the Pan American Health Organization (PAHO), quality standards were created in 1999 to contribute to Latin America’s blood safety [1]. The purpose of the standards is to provide safe blood for patients requiring transfusion therapy.
The blood component’s QC in blood banks has become a tool to monitor products’ production and ensure compliance with local and international standards [2]. In recent years, significant advances have been observed to improve the quality of blood components, including advances in international standards for the preparation of blood products, redefining the principles for high-quality production practices, establishing new parameters and reference values to guarantee quality in blood banks [3].
Unfortunately, establishing a quality control program and implementing it in blood banks, especially in Latin America, are not easy. There is still no clarity in the regulations to carry out this objective in several regions.
Therefore, it will be interesting to share the experience of three blood banks from Latin American countries: Banco de Sangre de Córdoba (Colombia), Centro de Sangre Valparaíso (Chile), and Banco de Sangre UMAE Puebla (Mexico), which have more than two years controlling the production of blood components through its quality control programs, welcoming compliance with local regulations in each country.
The production of red blood cells (RBCs) and platelet concentrates (PLs) in the three centers evaluated is similar, since the collection and processing of whole blood are aimed at obtaining RBC BC removed in additive solution (SAGM), PL from BC and plasma. These three institutions have been using Maco Pharma systems to obtain the mentioned blood components (Top and Bottom (T&B) Quadruple Bag MQT6285LS) for more than three years.
Colombian blood banks must comply with local regulations, established in the Manual of Technical Standards, administrative, and blood banks (Decree 1571/93) [4]. In 2012, Colombia’s National Institute of Health (NIH) published a technical document detailing the country’s quality control values compiled by all blood production centers [5]. Mexican blood banks must comply with the standards protocol established in the Official Mexican Standard NOM-253-SSA1-2012 to dispose of human blood and its components for therapeutic purposes [6]. Chilean institutions are supervised by the Ministry of Health, which in 1983 published the Standards for Blood Banks [7]. They establish the parameters to be followed to guarantee the adequate quality of the blood components produced in the country (Table 1 and Table 2).
Study design
An observational retrospective cross-sectional study was conducted with QC data of PL and RBC collected from three Latin American centers: Banco de Sangre UMAE—Puebla, Mexico, located in the city of Puebla (Calle 7 Sur 1510, Centro, 72000 Puebla, Pue., Mexico), collecting an average of 25,000 donors/year, and one of the most important IMSS (Instituto Mexicano de Seguro Social) institutions in this state; Banco de Sangre de Córdoba, Colombia, located in Montería city (Cra. 6 #26-08, Montería, Córdoba), with an average collection of 18,000 donors/year; and Centro de Sangre Valparaíso, Chile, located in the city of Valparaíso (Blas Cuevas 985 Subida, El Litre, Valparaíso, Chile), which collects approximately 48,000 donors/year.
The centers were chosen, taking into account that all three have similar processing methods, especially for obtaining platelets and the removal of the BC in the red blood cells with T&B system collection.
Red blood cell production on the three centers was carried out following the protocol for the Red Cells Buffy-Coat removed in additive solution [8], with initial hard spin centrifugation for the whole blood, to obtain beside the RBC, the BC removed, and plasma component. Once the BC was separated from white blood cell (WBC), platelets were obtained doing soft spin centrifugation, to comply with the steps to produce platelet, recovered, single units [8] (Table 3).
Data corresponding to one year of production was consolidated and analyzed. The study parameters seek compliance with European standards for RBC: Leukocytes count 9/mL; hematocrit >52%. For platelets: cell count >60 × 109/mL, leukocytes 8/mL [8].
Inclusion and exclusion criteria
Being a retrospective and observational study, we didn’t have exclusion criteria, since all the QC data collected was included into the analysis.
Laboratory tests
Each center performed the cellular count for QC with the following hematology analyzers:
Mexico: Swelab Alfa Standard—Boule Diagnostics (Spånga, Sweden)
Colombia: ABX Micros ES60—HORIBA Medical (Minami-ku, Kyoto, Japan)
Chile: Beckman Coulter FC500, Beckman Coulter (Brea, California)
Statistical analysis
Pearson’s Chi-square test analyzed the quality control parameters established in each country. The comparative analysis of the mean values in all centers was performed using Dunnett’s T3 test. All the tests were performed with bilateral contrast, considering the differences statistically significant when the error type was ≤ 0.05.
The number of cases, the arithmetic mean, the standard deviation, the median, the 95% confidence interval, and the minimum and maximum values were obtained from all the quantitative parameters evaluated in this statistical analysis.
The analyzed sample (N) was 1402 RBC, distributed by countries: Colombia 308 (22%), Chile 864 (61.6%), and Mexico 230 (16.4%). The total sample for platelet concentrates was 1245 units, distributed: Colombia 308 (24.7%), Chile 695 (55.8%), and Mexico 242 (19.4%).
The total compliance criteria of RBC for each parameter in all countries were Volume, 97.9%; HCT, 98.8%; Hb, 96.0 (only for Mexico and Chile), WBC, 97%. This means that the total compliance on RBC concentrates for all center parameters were Colombia, 98.7%; Mexico, 86.5% and Chile, 90.6%; for 91.7% (see Table 4).
Platelet concentrates compliance criteria for each parameter in all three countries were Volume, 100%; platelet count, 82.3%; pH, 99.2% (only for Colombia and Chile); WBC, 95.3%. According to these results, total compliance on platelet concentrates by center were Colombia, 99.7%; Mexico, 87.2%; Chile, 93.8% (see Table 5).
Daily blood component production faces a critical challenge, consisting of complying with the community’s transfusion needs and providing blood products with the quality required to promote all recipients’ recovery. Over the past two decades, the quality of blood components has improved remarkably, due to technological advances looking to optimize the collection and processing steps, guides, and manuals of world-renowned institutions that seek to lay the foundations to work with the necessary standards in all the regions [9].
As a characteristic of the Latin American region, it is known that developing countries face considerable obstacles to increase transfusion security. However, there are countries where this tendency has generated its need to adapt and adhere to international standards that, over the years, have proven to be of great help and guidance for the improvement in the production of blood components.
Some Latin American countries have focused on using the T&B methodology, increasing transfusion safety without investing much in resources. Chile, Colombia, and Mexico, in particular, have been adapting their routines toward European standards. This is reflected in local regulations, which are similar to the expected values of the European Directorate for the Quality of Medicine & Healthcare (EDQM).
The results of this study show us that three different countries in a region as large as Latin America can implement and carry out a QC program for their production of blood components and find significant similarities in their results, despite the population difference and all that this implies. This outcome reveals that the essential part of achieving these similarities was using a T&B technique: removing the BC layer of RBCs and obtaining platelets from the BC.
An important parameter to verify the quality of the RBC is the HCT value, which for the three countries involved found average values of (%): 60.3 ± 3.1 (Colombia), 57.8 ± 3.6 (Chile), and 59.9 ± 2.9 (Mexico). Results reveal very close values with a similar standard deviation (SD), even though it is essential to highlight that the mean HCT was significantly higher in the centers of Colombia and Mexico than in the center of Chile (p <0.05) (Table 6).
On the other hand, the residual leukocytes analyzed met 97% of the expected values in all countries (<1.2 × 109/mL), which indicates a production method that favors the quality of red blood cells. Detailing each result, we found that the average leukocyte count in red blood cell concentrates was significantly lower in Mexico’s institution than Colombia and Chile’s blood banks (p < 0.05) (Table 6).
The production of platelet concentrates can vary according to the preparation standards and methodology that each country establishes. However, compliance with the platelet count of 82.3% was achieved in the three institutions, which is the expected value in the local regulations of >55 × 109/mL for all three countries.
According to the results, we can conclude that the mean platelet count was significantly lower in Mexico’s blood bank than in Colombia and Chile (p < 0.05). In addition, the residual leucocytes evaluated in platelets concentrate were also complying with local standards. The mean residual leukocyte count in platelet concentrates was significantly lower in Colombia than Chile and Mexico (p < 0.05) (Table 7).
According to the QC results for three different countries included in this evaluation, we can conclude that the RBC with BC processing allows obtaining high-quality components, with a reduced concentration of leukocytes, complying with international standards (EU guidelines), which adds significant value in emergency transfusion situations, especially in countries with little experience using this type of processing.
It is also important to mention the results obtained by single platelet methodology preparation (from BC), which also complying with EDQM standards, demonstrating that this component is the right showed an excellent choice for transfusion therapy, and superior to other techniques still in used [10].
The results prove that by working with similar techniques, it is possible to obtain comparable values for blood components with quality in compliance with local and international standards, such as the data analyzed from the three countries mentioned in this article. It is also essential to highlight the importance of quality control programs in preparing blood components throughout the region, which will favor the adequate standardization of all countries’ implementation processes.
1.
Pan American Health Organization. Estándares de trabajo para servicios de sangre. 3ed. Washington, DC: 2012. [Available at: https://iris.paho.org/handle/10665.2/3266
2.
Jordan A, Chen D, Yi QL, Kanias T, Gladwin MT, Acker JP. Assessing the influence of component processing and donor characteristics on quality of red cell concentrates using quality control data. Vox Sang 2016;111(1):8–15. [CrossRef]
[Pubmed]
3.
Patel SN, Ranapurwala M, Shah M. Quality control of blood components-a step towards efficient supply of blood products. International Journal of Advanced Research 2016;4(4):570–2. [CrossRef]
4.
6.
7.
8.
9.
Sultan S, Zaheer HA, Waheed U, Baig MA, Rehan A, Irfan SM. Internal quality control of blood products: An experience from a tertiary care hospital blood bank from Southern Pakistan. J Lab Physicians 2018;10(1):64–7. [CrossRef]
[Pubmed]
10.
Singh RP, Marwaha N, Malhotra P, Das S. Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC) and apheresis-PC methods. Asian J Transfus Sci 2009;3(2):86–4.
[Pubmed]
We thank the three participating centers, which have worked for several years with the assembly of the quality control program, and continued to do so to guarantee the stability of their procurement process of blood production.
Author ContributionsDalia María Moreno Cardona - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Ludwig Frontier - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Ignacio Álvarez - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Yolanda Ibarra - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Yazmín Morales - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Alicia Alvarado - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Karin Martínez - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Nohora Cristancho - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Mary Rolón - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Zuly Hernández - Conception of the work, Design of the work, Acquisition of data, Analysis of data, Drafting the work, Revising the work critically for important intellectual content, Final approval of the version to be published, Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Guarantor of SubmissionThe corresponding author is the guarantor of submission.
Source of SupportNone
Consent StatementWritten informed consent was obtained from the patient for publication of this article.
Data AvailabilityAll relevant data are within the paper and its Supporting Information files.
Conflict of InterestAuthors declare no conflict of interest.
Copyright© 2020 Dalia María Moreno Cardona et al. This article is distributed under the terms of Creative Commons Attribution License which permits unrestricted use, distribution and reproduction in any medium provided the original author(s) and original publisher are properly credited. Please see the copyright policy on the journal website for more information.