![]() |
Original Article
| ||||||
Evaluation of erythrocyte autoantibodies with flow cytometric phagocytosis assay | ||||||
Shoichi Ito1, Tomoko Hishinuma1, Yoshiko Ogiyama1, Tomomi Asano1, Haruka Kagaya1, Michiyo Irino1, Hideya Hasegawa1, Hiroshi Shimizu1, Kenneth E. Nollet2, Masayoshi Minegishi3, Hitoshi Ohto2 | ||||||
1Japanese Red Cross Tohoku Block Blood Center, Sendai, Miyagi, Japan 2Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University, Fukushima, Japan 3Japanese Red Cross Fukushima Blood Center, Fukushima, Japan | ||||||
| ||||||
[HTML Abstract]
[PDF Full Text]
[Print This Article] [Similar article in PubMed] [Similar article in Google Scholar] |
How to cite this article |
Ito S, Hishinuma T, Ogiyama Y, Asano T, Kagaya H, Irino M, Hasegawa H, Shimizu H, Nollet KE, Minegishi M, Ohto H. Evaluation of erythrocyte autoantibodies with flow cytometric phagocytosis assay. Int J Blood Transfus Immunohematol 2018;8:100039Z02SI2018. |
ABSTRACT
| ||||||
Aims: Cellular assays such as the monocyte monolayer assay have been used to evaluate the clinical significance of antibodies to red blood cells (RBCs). Flow cytometry (FCM) has also been applied to antibody screening and diagnosing autoimmune hemolytic anemia (AIHA). Methods: RBC eluate from 131 patients with positive direct antiglobulin tests, along with three human monoclonal antibodies (two anti-D and one anti-Dib) were used to evaluate a new FCM two-color phagocytosis assay using markers that bind RBCs and monocytes. Dual-positive event percentages were compared with antibody titers and trimmed mean fluorescence intensity (MFI) from the 131 eluates and three monoclonal antibodies. Results: Percent positive by the FCM phagocytosis assay correlated well (R2=0.755) with trimmed-MFI in serial dilutions of two human IgG1 monoclonal antibodies, anti-D and anti-Dib, and 131 clinical samples with titers ranging from 2 to 2048. IgG2 antibodies showed lower phagocytosis relative to titers and MFI associated with these antibodies. Conclusion: The FCM phagocytosis assay can be used to evaluate AIHA-associated antibodies, with great potential to standardize immunohematology testing, especially in regard to establishing the clinical significance of RBC alloantibodies. Keywords: Direct anti-globulin test, Flow cytometry, IgG subclass, Phagocytosis | ||||||
INTRODUCTION
| ||||||
Red blood cells (RBCs) sensitized with IgG alloantibody are subject to removal and destruction via the mononuclear phagocyte system, which includes splenic macrophages. Among IgG subclasses (1–4 which differ in their constant regions), IgG3 has the strongest complement activity whereas IgG4 has the least. Blood monocytes migrate through vessel walls and differentiate into macrophages that express FcgRI receptors with high affinity for IgG1 and IgG3. Antibody-sensitized RBCs can be bound via the FcgR I receptor and subsequently phagocytosed by macrophages [1]. Conversely, IgG2-coated RBCs are hardly phagocytosed due tothe low affinity of IgG2 for the FcgR I receptor [2]. The monocyte monolayer assay (MMA) is an established tool for evaluating the clinical significance of blood group alloantibodies, thus informing the decision to transfuse, or not, RBCs incompatible with antibodies to high-incidence antigens [3]. RBCs with warm direct antibody positivity may vary in regard to autoantibody titer and IgG subclass [4][5]. In this study, to quantify associations between antibody titer, IgG subclass, and phagocytic activity, we developed a flow-cytometry (FCM) phagocytosis assay, and demonstrated its utility using clinical samples from direct-antibody test (DAT) positive RBCs and pooled monocytes. | ||||||
MATERIALS AND METHODS
| ||||||
Clinical samples, eluates from red blood cells, and antibody titration
Eluates from RBCs were obtained using Ortho DT Eluates II (Ortho Clinical Diagnostics, NJ, USA) according to the manufacturer’s instructions. Briefly, 1 mL of patient RBCs was washed with phosphate-buffered saline (PBS), then suspended in 1 mL of PBS, to which 2 mL of DT Eluates II were added. After mixing, the cell suspension was incubated for five minutes at 37ºC, and finally eluates were obtained after centrifugation. Eluate aliquots of 100 µL were mixed with 100 µL of 3% suspensions from a 3-cell panel mixture of R1R2 (DCe/DcE) RBCs, and low-ionic strength solution (LISS) was added for the indirect antiglobulin test. Antibody titer was determined by reactivity in the most diluted tube in two series of titrations with PBS. IgG subclass IgG subclass was determined by flow cytometry as described previously [6], with partial modification. Briefly, 2 µL of sedimented RBCs, 100 µL of eluate, and 100 µL of LISS were mixed and incubated at 37ºC for 15 minutes. After washing three times with PBS, 40 µL of 0.5% solution of sensitized RBCs and 100 µL of 10-fold diluted fluorescence-conjugated sheep anti-human-IgG1, IgG2, IgG3, IgG4 (The Binding Site, Birmingham, UK) or 6% albumin were added. After incubating for 30 minutes in the dark at room temperature, cells were washed once with 4 mL of phosphate buffered saline (PBS) to remove unbound antibodies. Flow cytometry (FCM) analysis was done using a FACS Calibur (Becton Dickinson, Tokyo). A total of 10,000 events for each sample were acquired.
Estimation of autoantibody-binding to RBCs
Phagocytosis assay with FCM
(2) Autoantibody sensitization to RBCs Autoantibody eluate and LISS (50 µL each)were added to 25 µL of PKH26-labeled RBC suspension, and incubated at 37ºC for 15 minutes. After washing three times, 500 µL of RPMI-1640 was added to the tube to prepare an autoantibody-sensitized and fluorescent RBC suspension. (3) Pooled monocyte suspension Mononuclear cells from ethylene diamine tetra acetic acid (EDTA)-anticoagulated whole blood from 20 healthy donors were separated by centrifugation over mononuclear cell separation reagent (Lymphoprep, Axis-Shield Poc As, Norway). Then, monocytes were purified using monocyte selection reagent (EasySep Human CD14 Positive Selection kit, Stem Cell Technologies, Canada) according manufacturer’s instructions. Monocytes were finally suspended in RPMI at a concentration of 1,000/µL. (4) FCM phagocytosis A mixture of 500 µL of autoantibody-sensitized RBC suspension and 500 µL of pooled monocyte suspension was stirred and incubated at 37ºC in a CO2 incubator for one hour, and then supernatant was removed after centrifugation for three minutes at 3000 rpm. Thereafter, to hemolyze non-phagocytosed RBCs, 1 mL of hemolysis solution (Lysing Solution, Becton Dickinson, Tokyo) was added to the cell pellet and kept for 10 minutes at room temperature. After washing, monocytes were fluorescence-labeled with 25 µL FITC Mouse Anti-Human CD14 (Becton Dickinson, Tokyo) at 4ºC for 30 minutes. Monocytes and RBCs were detected by FITCfluorescence in FL1 and PKH26 fluorescence at FL2, respectively. Among 2,000 events per FITC fluorescence, the PKH-positive percentage was interpreted as a measure of phagocytosis. Eluates obtained from DAT-negative RBCs were used as negative controls. Two human monoclonal IgG1 antibodies, anti-D (HIRO-3, JRCS, Tokyo)[7] and anti-Dib (JRCS) were used as positive controls, along with one human monoclonal IgG2 anti-D (JRCS) as a reference. (5)nbsp;nbsp;Reproducibility of assays To confirm the obtained results, we assayed three times using different monocytes sources and three human monoclonal antibodies, two anti-D and one anti-Dib, at a range of titers from 4 to 1,024.
Statistical analysis
| ||||||
RESULTS | ||||||
Preliminary assessment of the flow cytometry-phagocytosis assay
For reproducibility, the percent positive measure of phagocytosis was repeated three times using two human monoclonal antibodies, one anti-D and one anti-Dib, without statistically significant differences at 8 antibody titers from 4 to 1,024 with coefficient of variance between 0.02 and 0.38 using an anti-D of subclass IgG1 and between 0.01 and 0.43 using an anti-Dib (data not shown). As shown in Figure 2, similar phagocytosis results were obtained when monocytes obtained from 3 different pools of donors were used at a constant monocyte concentration of 1,000 /µL. Phagocytosis activity increased sharply at antibody titers of 32 and 64, and plateaued around 90% at titers of 128 and 258.
Comparison between antibody titer of eluates and FCM-phagocytosis assay
Comparison between MFI and phagocytic activity
The correlation coefficient R2 = 0.755 showed good correlation between autoantibody MFI, and FCM-phagocytosis activity.
IgG subclass and FCM-phagocytosis activity
Trimmed MFI of samples “a” and “b” of Figures 4 and 5 of single IgG2 subclass was 846.9 and 711.4, respectively, which can be theoretically sufficientfor good FCM-phagocytosis activity. However, FCM-phagocytosis activities were low,at 4.1% and 6.2% (shown in Figures 4 and 5), respectively. Two other samples,predominantly IgG2 with lesser content of other subclasses, both at antibody titers of 32, showed lower phagocytic activity, 2.1% and 7.7%, than the mean phagocytosis activity of 14.6% of others at the same titer, and comparable to trimmed-MFI values observed in the two samples. Two cases with single IgG3 subclass titers of 2 and 16 did not show any increased phagocytic activity. Mixed subtypes including IgG3 were found in 34 cases (26%), all which co-existed with a predominant IgG1, and showed no increased phagocytic activity. | ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
DISCUSSION | ||||||
FCM is more sensitive than tube or gel column agglutination for detecting RBC-bound IgG or complement, especially to diagnose DAT-positive autoimmune hemolytic anemia (AIHA) and to predict hemolysis in DAT-negative patients with AIHA [8], [9], [10], [11]. The relative amounts of RBC-bound immunoglobulin and complement, and determination of IgG subclass, can be measured by FCM [1], [5],[12]. Monocyte monolayer assay using live monocytes is regarded as highly useful in determining the clinical significance of antibodies by observing phagocytosis of sensitized RBCs [3],[13],[14]. In this report, we introduce a unique FCM-phagocytosis assay, in which phagocytic activity of an antibody can be quantified, by counting double positive events with RBC-bound PKH26 and monocyte-bound FITC after incubation of sensitized RBCs with live monocytes. In this study, we compared titers of autoantibodies eluted from RBCs of AIHA patients, and MFI against allogeneic RBCs and found MFI to be the strongestcorrelate of phagocytic response. Zupanska et al reported that IgG3 and IgG1 on RBC membranes were closely correlated to MMA results [15]. Dubarry et al concluded that warm (IgG) AIHA had three times the number of IgG molecules per RBC than DAT-positive RBCs with no hemolysis, and hemolysis correlated with higher numbers of antibodies on the RBC membrane [16]. In this study, we found that phagocytic activity correlated well with antibody titer, especially titers from 32 to 128 plateauing at 128 with a slight increase in phagocytic activity at higher titers. As previously reported [3], IgG2 antibodies, with or without the incidental presence of other subclasses, brought about little phagocytic activity, because IgG2 and IgG4 antibodies are not efficiently recognized by the mononuclear phagocyte system. We adapted FCM to evaluate antibody-mediated phagocytic activity, as FCM is well-established for its objectivity in measuring antibody intensity. At present, a weak point of FCM in this application is that cut-off values need to be established. In the standard MMA, positive, negative, and indeterminate values are set at 20% or more, 5% or less, and between 5.1% and 19.9%, respectively [3]. In our previous study, the cut-off value for MMA was set at 1% [17]. In the present study, we investigated whether the FCM-phagocytosis assay correlates with standard MMA using 7 samples, and found that indeterminate values of MMA clustered around 50% by FCM-phagocytosis, and tentatively propose cut-off values of 60% or more, 40% or less, and values in-between for positive, negative and indeterminate, respectively. | ||||||
CONCLUSION
| ||||||
AIHA – associated antibodies can be evaluated with FCM phagocytosis assay. Additional studies of alloantibodies with and without clinical significance will refine our ability to anticipate clinical outcomes with a laboratory test, and establish cut-off values and correlation for patients with AIHA and other manifestations of disordered immunohematology. | ||||||
REFERENCES
| ||||||
|
[HTML Abstract]
[PDF Full Text]
|
Author Contributions
Shoichi Ito – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published Tomoko Hishinuma – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Final approval of the version to be published Yoshiko Ogiyama – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Final approval of the version to be published Tomomi Asano – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Final approval of the version to be published Haruka Kagaya – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Final approval of the version to be published Michiyo Irino – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Final approval of the version to be published Hideya Hasegawa – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Final approval of the version to be published Hiroshi Shimizu – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Final approval of the version to be published Kenneth E. Nollet – Analysis and interpretation of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published Masayoshi Minegishi – Substantial contributions to conception and design, Acquisition of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published Hitoshi Ohto – Substantial contributions to conception and design, Analysis and interpretation of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published |
Guarantor of Submission
The corresponding author is the guarantor of submission. |
Source of Support
None |
Consent Statement
Written informed consent was obtained from the patient for publication of this study. |
Conflict of Interest
Author declares no conflict of interest. |
Copyright
© 2018 Shoichi Ito et al. This article is distributed under the terms of Creative Commons Attribution License which permits unrestricted use, distribution and reproduction in any medium provided the original author(s) and original publisher are properly credited. Please see the copyright policy on the journal website for more information. |
|